Illumina

ILLUMINA

The ILLUMINA series street fixtures arise from continuous research for innovative solutions and the use of state-of-the-art technologies. Their design has focused on making their use extremely simple and meeting any application, ensuring the highest quality standards and high luminous efficiency. The structure is made of anodized aluminum with a salt-resistant treatment. The painting, made with epoxy powders, makes them particularly durable and reliable over time. The modern and minimal design allows for easy placement in various applications.

WHERE TO APPLY THEM?

• Urban Streets
• Sub-urban Streets
• Bike Lanes
• Parking
• Traffic circle 

STANDARD EQUIPEMENT

• DOWBLE PROTECTION from electric shock until to 10KV;

• DOUBLE INSULATED OPENING SELECTOR;

• ANTI-CONDENSATE VALVE to air recirculation;

• DIFFUSIONE DELLA LUCE con sistema Multilayer;

• MODULAR OPTICAL GROUP, easily replaceable; 

• POWER SOURCE GROUP, easily replaceable.

OPTICAL GROUP

The Optical group ensurances compliance with the standards EN62471:2008, so it is free of photo-biological risk. The design of the lamp and its reflector determines the full CUT-OFF photometric classification.

FLOW RECOVERER

The flow recoverer is made of polycarbonate (Vo) with finishis on galvanize aluminium capable of reducing the glare effects typical of LED lamps.

Alle optics are made with PMMA , with high light trasmission  T(λ)>90%, resistant to UV rays and high temperature.

ILLUMINA Led CCT 4000K

CODESSOURCEPOWER (W)NOMINAL FLOW (Lm)WEIGHT (Kg)PACKAGING (cm)
AS01015S4LED I16-CR415W22205.3056x27x16
AS01020S4LED I16-CR420W29605.3056x27x16
AS01025S4LED I16-CR425W37005.3056x27x16
AS01030S4LED I16-CR430W44405.3056x27x16
AS01035S4LED I16-CR435W51805.3056x27x16
AS01040S4LED I16-CR440W59205.3056x27x16
AS01045M4LED I24-CR445W66608.3067x34x19
AS01050M4LED I24-CR450W74008.3067x34x19
AS01055M4LED I24-CR455W81408.3067x34x19
AS01060M4LED I24-CR460W88708.3067x34x19
AS01065M4LED I24-CR465W96008.3067x34x19
AS01070M4LED I24-CR470W103408.3067x34x19
AS01080M4LED I48-CR480W118308.7067x34x19
AS01090M4LED I48-CR490W133208.7067x34x19
AS01100M4LED I48-CR4100W148308.7067x34x19
AS01120L4LED I72-CR4120W1776014.6088x41x23
AS01135L4LED I72-CR4135W1997014.6088x41x23
AS01140L4LED I72-CR4142W2102014.6088x41x23
AS01150L4LED I72-CR4150W2220014.6088x41x23

ILLUMINA Led CCT 3000K

CODESSOURCEPOWER (W)NOMINAL FLOW (Lm)WEIGHT (Kg)PACKAGING (cm)
AS01015S3LED I16-CR315W22205.3056x27x16
AS01020S3LED I16-CR320W27205.3056x27x16
AS01025S3LED I16-CR325W34005.3056x27x16
AS01030S3LED I16-CR330W41005.3056x27x16
AS01035S3LED I16-CR335W47605.3056x27x16
AS01040S3LED I16-CR340W54505.3056x27x16
AS01045M3LED I24-CR345W61308.3067x34x19
AS01050M3LED I24-CR350W68008.3067x34x19
AS01055M3LED I24-CR355W74908.3067x34x19
AS01060M3LED I24-CR360W81608.3067x34x19
AS01065M3LED I24-CR365W88308.3067x34x19
AS01070M3LED I24-CR370W95008.3067x34x19
AS01080M3LED I48-CR380W109008.7067x34x19
AS01090M3LED I48-CR390W122508.7067x34x19
AS01100M3LED I48-CR3100W136438.7067x34x19
AS01120L3LED I72-CR3120W1634014.6088x41x23
AS01135L3LED I72-CR3135W1837014.6088x41x23
AS01140L3LED I72-CR3142W1934014.6088x41x23
AS01150L3LED I72-CR3150W2042014.6088x41x23

POWERFrom 20W to150W
VOLTAGE 230Vac
INSULATION CLASSI – II
POWER FACTOR≥0,98
FREQUENCY 50/60Hz
TEMPERATURE-40°C + 50°C
ENERGETIC CLASSA++

BARK Alluminum
FIXING POLE Ф 60mmRegolabile 0°-90°±10°
PROTECTION GRADEIP66
IMPACT PROTECTION GRADEIK09
COLOR GRIGIO RAL 9007

LED CHIPPhilips Lumileds
LUMINOUS EFFICIENCY84%
CROMATIC YIELD INDEX≥70
COLOR TEMPERATURE4000K
3000K optional
PHOTOBIOLOGICAL CLASSGRUPPO ESENTE
PHOTOMETRIC CLASSfull CUT-OFF
OPTICAL GROUP DURATION>100.000h – L90B10
OPTICSOTS-AS; OTS-BS; OTS-CS; OTS-DS; OTS-PS
POWERFrom 20W to150W
VOLTAGE 230Vac
INSULATION CLASSI – II
POWER FACTOR≥0,98
FREQUENCY 50/60Hz
TEMPERATURE-40°C + 50°C
ENERGETIC CLASSA++

Possible dimming options with optional equipment


D1: Reduction of flow after virtual midnight in relation to predetermined steps set in the factory.
D2: Adjustment of flow using a 1-10V pilot signal from a remote controller.
D3: DALI (Digital Addressable Lighting Interface) dimming via signal managed by a remote control.
D4: Adjustment of flow using a wireless telecontrol interface for remote management.